Menu Products
   Contact us
KENMEC VIETNAM CO., LTD
Address: Thach That-Quoc Oai Industrial zone, Quoc Oai District, HaNoi city, VietNam
TEL: 84-4-33940868
FAX: 84-4-33940997
Email: kenmec@kenmec.com.vn
Website: www.kenmec.com.vn
Skype: vnfuchung/kmvn018

   SUPPORT ONLINE

kmvn030-Automation


kmvn018-Automation


kmvn029-Solar water heater, Electric water heater


kmvn021-Support information


vnfuchung-Support information

   Porcelain enamel inner tank
Porcelain enamel inner tank

Model: KM-SPO
Name: solar tank
Type: high pressure
OEM: welcome
MOQ:1 set
Lead time:15 days
Brand: GREEN SOLAR
Payment: L/C ,T/T
Price term: DDP ,CIF ,FOB
Simple Product Description

Model: WTO-SPO
Pressurized & separated porcelain enamel solar tank with one coil

Tank volume : 150L -500L (40gal -130gal)

Copper coil: One

 
Detailed Product Description

Solar tank ( pressure solar Split Porcelain enamel tank with One coil )

Model : WTO-SPO

1) Tank volume: 150 L ,200 L, 300 L, 400 L, 500 L (40gal -130gal)

2) Outer tank: Colored Steel Sheet ,Thickness: 0.5mm

3) Inner tank: Titanium Steel 2 & 3 mm and Enamel Coating 0.5mm

4) Insulation: polyurethane foam thickness: 40-45mm

5) Copper coil: thickness: 1mm; diameter: 16mm ; Optional: 22mm

6) Tank Include: E-heater ,Mg Anode ,T&P Valve ,relief valve, Drain valve ,Sensor

7) Inlet/Outlet/Drain/Circulating inlet/Circulating outlet: 3/4 inch

8) Working pressure: 0.6 Mpa Test pressure: 1.2Mpa

Model

Tank volume

Inner tank thickness

E-heater

Foam

coil (length) (Φ16mm)

Qty.(Sets)

20"

40HQ

WTO-SPO-150

150L/40gal

2mm

1.5 kw

45mm

0.6㎡ /12m

52

112

WTO-SPO-200

200L/50gal

2mm

1.5 kw

40mm

0.6㎡ /12m

27

78

WTO-SPO-300

300L/80gal

2mm

1.5 kw

40mm

0.7㎡ /14m

27

78

WTO-SPO-400

400L/105gal

3mm

2.5 kw

45mm

0.8㎡ /16m

21

66

WTO-SPO-500

500L/130gal

3mm

2.5 kw

45mm

0.8㎡ /16m

21

63

 

Active –closed loop systems pump heat-transfer fluids (usually a glycol-water antifreeze mixture) through collectors .Heat exchangers transfer the heat from the fluid to the household water stored in the tank.

Closed loop glycol systems are popular in areas subject to extended freezing temperatures because they offer good freeze protection .How ever ,glycol antifreeze are a big more expensive to buy and install. And the glycol must be checked each year and changed every 3 to 10years,Depending on glycol quality and system temperatures.

 
 
 


      Need more ,Please contact us ,Thanks!
    Other Products
KENMEC VIET NAM CO., LTD
Address: Thạch That - Quoc Oai Industrial zone, Ha Noi, Viet Nam
TEL: 84-4-33940868 FAX: 84-4-33940997
Email: kenmec@kenmec.com.vn - Website: www.kenmec.com.vn